Clinical Workflow
How MOSkin Works
A streamlined, 4-step workflow that delivers real-time skin-dose verification in 3-5 minutes—without disrupting standard treatment protocols.
4-Step Process
The Complete Workflow
1
Prepare Sensor
~120 seconds
Perform a baseline of the sensor and assign placement regions.
2
Place Sensor
~60 seconds
Clean skin surface and apply single-use MOSkin sensor to treatment site.
- Sensors are thin and radio-translucent
- Photo-document placement for verification
- Compatible with immobilization masks
- No cables over the patient
3
Position Patient & Treat
Standard treatment time
Complete standard patient positioning and deliver treatment fraction as planned.
- Normal treatment workflow
- Up to 4 sensors can be used simultaneously
- Sensors remain in place during treatment
4
Cable-Free Data Capture
~30 seconds
HUB reads sensor data after treatment completion and transmits to the Monitor.
- Reader stays at console (close to treatment room)
- Automatic data transfer to iPad app
- No need to access patient after treatment
- Real-time processing
5
View Results & Report
~90 seconds
Review dose verification on iPad and receive automated report via email.
- Clear dose display at console
- Automated treatment report generation
- Ready for next fraction
- Photo record included
- Email delivery to clinician.
Total Time: 3-5 Minutes
Compare to traditional TLD workflows: 18-24 hours for oven processing, spreadsheet analysis, and multiple handling steps. MOSkin delivers results before the patient’s next fraction.
Workflow Integration
MOSkin fits seamlessly into existing treatment protocols without disruption.
Before Treatment
- Standard patient preparation
- Apply MOSkin sensor (~30 sec)
- Photo-document placement
- Complete positioning
During
- Normal treatment delivery
- Minimal workflow disruption
- Cable-free data capture
- Patient comfort maintained
After Treatment
- View results at console
- Automated report generated
- Email delivery to clinician
- Ready for next fraction
Frequently Asked Questions
Common questions about the MOSkin workflow and integration.
How long does the complete workflow take?
From setup to results takes only minutes. MOSkin delivers dose verification immediately after treatment, allowing clinicians to confirm readings without waiting for off-site processing.
Can MOSkin be used with immobilization devices?
Yes. The sensor’s thin, flexible profile allows it to fit comfortably beneath most immobilization devices without affecting setup or patient comfort.
How many sensors can be used at once?
Multiple sensors may be used simultaneously depending on clinical need, treatment site, and the verification objectives of the session.
Do sensors require sterilization between uses?
No. Sensors are designed to be single-use.
Where does the reader need to be positioned?
The reader does not need to be physically adjacent to the patient. The reader should be located in a nearby location, such as a control room.
Is MOSkin available in the United States?
Yes. MOSkin is FDA-cleared, and Electrogenics Laboratories operates under an ISO 13485–certified quality system.